HM-SN-1

Specification 10 Year Kitchen Heat Alarm, Mains Powered

Fire Sensing 5 Year Warranty Kitemark Grade D1 Mains Powered

Product description

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced sensing technology including Smart RF interlink ensuring your domestic installations are safe for years to come.

Our mains powered Specification heat alarm also comes with a 10 year sealed life battery as standard, provides class A1 heat detection (54°C-65°C), and has been designed with a unique Thermistek heat sensing technology combined with a patented radiant heat dish, high performance thermistor and predictive monitoring to ensure a quicker response to kitchen fires.

  • Mains powered with sealed 10 year lithium battery back-up
  • For use in kitchen, garage and loft
  • Provides class A1 heat detection (54°C-65°C) and features Thermistek technology, with a unique radiant heat dish, for a faster response to fire
  • BS 5446-2:2003
  • Compatible with our Connected Home Solution, with a Gateway  added to the network
  • Create a network with Smart RF – Fit a Smart RF Module for wireless compatibility to interlink multiple Specification alarms
  • Supplied with a dust cap to prevent dust or paint entering a device during installation or building projects to maximise longevity of the alarms
  • Our FireAngel Specification range sets the standard for performance, meets current legislation and fulfils the needs of all domestic projects for social housing
MoreLess

GET IN TOUCHPRODUCT SUPPORT

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced sensing technology including Smart RF interlink ensuring your domestic installations are safe for years to come.

Our mains powered Specification heat alarm also comes with a 10 year sealed life battery as standard, provides class A1 heat detection (54°C-65°C), and has been designed with a unique Thermistek heat sensing technology combined with a patented radiant heat dish, high performance thermistor and predictive monitoring to ensure a quicker response to kitchen fires.

Installation & Setup

Get the help and support you need to easily set up and install your FireAngel alarm for instant protection.

Installation guide

Installation guide

Click the icon for installation support

Build a network

Build a network

Click the icon to learn how to build a network

Resources

For more technical and specification information on this alarm, view our manual and datasheet.

Product manual

Product manual

Click the icon to download the product manual

Datasheet

Datasheet

Click the icon to download the product datasheet

Related FAQs

Heat alarms, like the Thermistek Heat Sensing Alarm, are ideal for kitchens, garages, or unconverted lofts. These areas benefit from the reduced likelihood of false alarms caused by fumes or dust.

A Grade D1 system is required for:
  • New or materially altered dwellings, up to three storeys with no floor exceeding 200 m2.
  • Existing dwellings with poor or inadequate fire protection, up to three storeys with no floor exceeding 200 m2.
  • Individual dwelling units of two or more rooms in Houses in Multiple Occupation (HMOs) of one or two-storeys, with no floor exceeding 200 m2.
There are three Levels of Detection (LD). Generally the greater the fire risk the more comprehensive the system should be.
LD1 = Maximum Protection. Alarms in all circulation spaces that form part of escape routes and all areas where a fire might start.
LD2 = Medium Protection. All circulation spaces and escape routes (e.g.hallways and landings) are covered together with a provision of higher fire risk areas (e.g.kitchen and living rooms).
LD3 = Minimum Protection. Alarms in all circulation spaces that form part of escape routes.
* Ensure that a Grade D1 system is adequate for the dwelling you are installing the alarms in. You can obtain further information from your local fire service or building control department at your local council offices.
Whilst BS 5839‑6 has previously been split into six varying Grades, each outlining the level of protection appropriate for certain properties and their corresponding levels of risk, the new update has altered the six sections, removing Grade B and Grade E, whilst Grade D and Grade F have been split into Grade D1 / Grade D2 and Grade F1 / Grade F2 respectively. Grade C has been revised and its recommendations expanded.
The 2019 grading system is as follows:
Grade A
Separate detectors, sounders and central control and indicating equipment with back-up power supply that conforms to British Standards BS EN 54.
Grade C
Separate detectors and sounders that are mains powered with back-up power supply and central control equipment.
Grade D1
A system of one or more mains powered detectors, each with a tamper‑proof standby supply consisting of a battery or batteries (such as FireAngel’s SM-SN-1 and HM-SN-1 alarm).
Grade D2
A system of one or more mains-powered detectors, each with an integral standby supply consisting of a user‑replaceable battery or batteries. (such as FireAngel’s SW1-PF-T and HW1-PF-T alarm).
Grade F1
A system of one or more battery-powered detectors powered by a tamper‑proof primary battery or batteries (such as FireAngel’s ST-622T, ST-750 alarm).
Grade F2
A system of one or more battery-powered detectors powered by a user‑replaceable primary battery or batteries. (such as FireAngel’s SB1-T alarm).
Please note: Grades B and E are no longer defined in BS 5839-6:2019.

FireAngel Smart RF technology allows alarms to communicate wirelessly. When one alarm detects a hazard, all interconnected alarms will sound simultaneously, ensuring full-home coverage.

If you choose not to add a Gateway upon initial installation, you can add a Gateway to an existing network at any time in the future – this will allow for remote monitoring of devices as the Gateway will communicate with the FireAngel App using an internet connection, however, if the internet connection fails or cuts out the alarms will still continue to work and protect property, no internet connection means you will no receive any push notifications whilst the internet is not working.
See all faqs

Extend Your Protection

Smart RF Technology: When one alarm sounds, they all sound. Our Specification range features Smart RF technology, allowing easy setup of wireless or hybrid networks of mains and battery devices for full property protection. Specification products offer three levels of unrivalled protection, the range can be upgraded at any time to meet tenant needs or new regulations, setting the standard for performance.

Consider a connected solution: Add a Connected gateway to the Specification range, offering 24/7 remote monitoring. Designed for social housing or private landlords to ensure maximum protection and compliance across a property portfolio. The free FireAngel app provides real-time updates and notifications without needing property access. We have safety solutions for every need.

align-media-2
Kitchen Heat Alarm image

HW10-EUT

Kitchen Heat Alarm

With nearly 50% of fires starting in the kitchen, it's vital to ensure protection in the most...

Pro Connected Smart Accessible Control Unit, Battery Powered image

FP1014W2-R

Pro Connected Smart Accessible Control Unit, Battery Powered

With enhanced sensing, multiple installation styles & the option to enable alerts & test...

FireAngel Pro Connected App image

app-1

FireAngel Pro Connected App

With enhanced sensing, multiple installation styles & the option to enable alerts & test...

Specification 10 Year Multi‑Sensor Smoke Alarm, Battery Powered image

FS2126-T

Specification 10 Year Multi‑Sensor Smoke Alarm, Battery Powered

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced...

Pro Connected Kitchen Heat Alarm, Mains Powered image

FP1740W2-R

Pro Connected Kitchen Heat Alarm, Mains Powered

With enhanced sensing, multiple installation styles and the option to enable alerts and test via...

Kitchen Heat Alarm image

HW1-R

Kitchen Heat Alarm

Looking for a FireAngel HT‑630 alarm replacement? Replace your end of life alarm with the...

Got a burning question? Get in touch

If you can't find what your looking for on our blogs and looking for further guidance and advice, our UK-based Customer Support team are on hand all week from 8:30am until 5:30pm, they can answer any further queries you may have on our products, solutions or services.

Related Support Posts

Committed to improving our environmental... image

Company

Committed to improving our environmental...

FireAngel has achieved a BSI certified ISO 14001 Environmental Management System which reflects our...

Damp and Mould Safety eBook image

Downloads

Damp and Mould Safety eBook

Perfect as a handy reference for landlords, or a shareable resource with tenants, download this...

Meet the team: Get to know Andrew Beechener image

Company

Meet the team: Get to know Andrew Beechener

FireAngel's team of Business Development Managers offer a wealth of knowledge and experience across...

Giving back: FireAngel’s IT Manager... image

Community support

Giving back: FireAngel’s IT Manager...

Derek is usually our resident IT wizard who can be found sorting out computers or updating systems,...

What the Renters’ Rights Bill means for UK... image

New Build

What the Renters’ Rights Bill means for UK...

The upcoming Renters’ Rights Bill represents a significant shift in the UK’s private rental...

FireAngel stands with the NEA on fuel... image

Community support

FireAngel stands with the NEA on fuel...

As temperatures drop and energy prices remain alarmingly high, FireAngel is proud to support...