SB1-T

Optical Smoke Alarm

Grade F2 3 Year Warranty Kitemark Battery included

Product description

Our SB1 optical standalone smoke alarm is ideal for grade F2 installations where cost is a priority and basic fire protection is required.

Optical alarms are recommended in the British Standard BS 5839‑6 for installation in circulation areas such as hallways and landings.

  • 1 year replaceable battery
  • 10 year product life
  • For use in hallway, landing, living room, dining room and bedroom
  • Optical sensor as recommended by BS 5839-6
  • BS EN 14604:2005+AC:2008
  • Grade F2 – Suitable for low-cost budget installations requiring basic fire protection
  • Easy installation – A quick and easy solution that provides instant protection with no interlinking required
MoreLess

GET IN TOUCHPRODUCT SUPPORT

Our SB1 optical standalone smoke alarm is ideal for grade F2 installations where cost is a priority and basic fire protection is required.

Optical alarms are recommended in the British Standard BS 5839‑6 for installation in circulation areas such as hallways and landings.

Installation & Setup

Get the help and support you need to easily set up and install your FireAngel alarm for instant protection.

Installation guide

Installation guide

Click the icon to find out more about installing your pro connected app

Maintenance guide

Maintenance guide

Click the icon to find out how to maintain and test your alarm

Resources

For more technical and specification information on this alarm, view our manual and datasheet.

Product manual

Product manual

Click the icon to download the product manual

Datasheet

Datasheet

Click the icon to download the product datasheet

Related FAQs

Whilst BS 5839‑6 has previously been split into six varying Grades, each outlining the level of protection appropriate for certain properties and their corresponding levels of risk, the new update has altered the six sections, removing Grade B and Grade E, whilst Grade D and Grade F have been split into Grade D1 / Grade D2 and Grade F1 / Grade F2 respectively. Grade C has been revised and its recommendations expanded.
The 2019 grading system is as follows:
Grade A
Separate detectors, sounders and central control and indicating equipment with back-up power supply that conforms to British Standards BS EN 54.
Grade C
Separate detectors and sounders that are mains powered with back-up power supply and central control equipment.
Grade D1
A system of one or more mains powered detectors, each with a tamper‑proof standby supply consisting of a battery or batteries (such as FireAngel’s SM-SN-1 and HM-SN-1 alarm).
Grade D2
A system of one or more mains-powered detectors, each with an integral standby supply consisting of a user‑replaceable battery or batteries. (such as FireAngel’s SW1-PF-T and HW1-PF-T alarm).
Grade F1
A system of one or more battery-powered detectors powered by a tamper‑proof primary battery or batteries (such as FireAngel’s ST-622T, ST-750 alarm).
Grade F2
A system of one or more battery-powered detectors powered by a user‑replaceable primary battery or batteries. (such as FireAngel’s SB1-T alarm).
Please note: Grades B and E are no longer defined in BS 5839-6:2019.

No, the SB1-T is a standalone battery-powered optical smoke alarm with no interlink options. This unit cannot be interlinked with any other products – please see our FireAngel Specification range or our FireAngel Mains with 9V battery backup range, both of these ranges offer hardwire and wireless interlink options.

According to latest BS 5839‑6 standards, for maximum LD1 protection you should fit a smoke alarm in the following rooms: Hallway, Landing, Living Room, Bedroom, Airing / Meter Cupboards, Loft, Garage. A smoke alarm is not recommended for installation in a kitchen, you should install a heat alarm in kitchens.
For further guidance on BS 5836‑6, please visit our Standards and Regulations Section.

For maximum protection for private rental properties smoke alarms must be installed on every floor where there is living accommodation (e.g., bedrooms, living rooms, hallways)
Heat alarms should be installed in kitchens and areas prone to false alarms.
Carbon monoxide alarms must be fitted in rooms with solid fuel appliances (e.g., wood-burning stoves, coal fires). Consider installing interconnected alarms to increase safety, especially in larger properties or properties with multiple tenants.

See all faqs

Extend Your Protection

Protecting your properties and tenants is easier than ever with our range of smoke, heat, and carbon monoxide alarms. To ensure complete coverage, it’s essential to make sure you’re installing best practice and ensure compliance with your regional fire & CO safety laws.

For added peace of mind, upgrade to our Specification Range. These smart alarms, designed for social housing, can be interlinked (via hardwire or wireless) so when one alarm is triggered, all alarms in the property sound. Landlords can monitor and manage alarms remotely via the FireAngel Connected app, receiving device data and notifications without needing access to the property. The free app also allows for easy testing and instant notifications, showing the status of alarms, e.g. if they’ve been removed or need maintenance.

Get in touch today to see how our FireAngel Connected solution can support you and your tenants.

social-housing
Kitchen Heat Alarm image

HW10-EUT

Kitchen Heat Alarm

With nearly 50% of fires starting in the kitchen, it's vital to ensure protection in the most...

Pro Connected Smart Accessible Control Unit, Battery Powered image

FP1014W2-R

Pro Connected Smart Accessible Control Unit, Battery Powered

With enhanced sensing, multiple installation styles & the option to enable alerts & test...

FireAngel Pro Connected App image

app-1

FireAngel Pro Connected App

With enhanced sensing, multiple installation styles & the option to enable alerts & test...

Specification 10 Year Multi‑Sensor Smoke Alarm, Battery Powered image

FS2126-T

Specification 10 Year Multi‑Sensor Smoke Alarm, Battery Powered

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced...

Pro Connected Kitchen Heat Alarm, Mains Powered image

FP1740W2-R

Pro Connected Kitchen Heat Alarm, Mains Powered

With enhanced sensing, multiple installation styles and the option to enable alerts and test via...

Kitchen Heat Alarm image

HW1-R

Kitchen Heat Alarm

Looking for a FireAngel HT‑630 alarm replacement? Replace your end of life alarm with the...

Got a burning question? Get in touch

If you can't find what your looking for on our blogs and looking for further guidance and advice, our UK-based Customer Support team are on hand all week from 8:30am until 5:30pm, they can answer any further queries you may have on our products, solutions or services.

Related Support Posts

Committed to improving our environmental... image

Company

Committed to improving our environmental...

FireAngel has achieved a BSI certified ISO 14001 Environmental Management System which reflects our...

Damp and Mould Safety eBook image

Downloads

Damp and Mould Safety eBook

Perfect as a handy reference for landlords, or a shareable resource with tenants, download this...

Meet the team: Get to know Andrew Beechener image

Company

Meet the team: Get to know Andrew Beechener

FireAngel's team of Business Development Managers offer a wealth of knowledge and experience across...

Giving back: FireAngel’s IT Manager... image

Community support

Giving back: FireAngel’s IT Manager...

Derek is usually our resident IT wizard who can be found sorting out computers or updating systems,...

What the Renters’ Rights Bill means for UK... image

New Build

What the Renters’ Rights Bill means for UK...

The upcoming Renters’ Rights Bill represents a significant shift in the UK’s private rental...

FireAngel stands with the NEA on fuel... image

Community support

FireAngel stands with the NEA on fuel...

As temperatures drop and energy prices remain alarmingly high, FireAngel is proud to support...