SM-SN-1

Specification 10 Year Thermoptek Smoke Alarm, Mains Powered

Fire Sensing 5 Year Warranty Kitemark Grade D1 Mains Powered

Product description

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced sensing technology including Smart RF interlink ensuring your domestic installations are safe for years to come. Grade D1 as recommended by BS 5839‑6.

Our unique patented Thermoptek technology combines the latest optical sensing with thermal enhancement for rapid detection to all fires.

  • Mains powered with sealed 10 year lithium battery back-up
  • For use in hallway, landing, living room, dining room and bedrooms
  • Contains optical sensing Thermoptek patented technology, for rapid detection to all types of fires
  • BS EN 14604:2005+AC:2008
  • Compatible with our Connected Home Solution, with a Gateway added to the network
  • Create a network with Smart RF wireless interlink – fit a Smart RF Module for wireless compatibility to interlink multiple Specification alarms
  • Supplied with a dust cap to prevent dust or paint entering a device during installation or building projects to maximise longevity of the alarms
  • Our FireAngel Specification range sets the standard for performance, meets current legislation and fulfils the needs of all domestic projects for social housing
MoreLess

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced sensing technology including Smart RF interlink ensuring your domestic installations are safe for years to come. Grade D1 as recommended by BS 5839‑6.

Our unique patented Thermoptek technology combines the latest optical sensing with thermal enhancement for rapid detection to all fires.

Installation & Setup

Get the help and support you need to easily set up and install your FireAngel alarm for instant protection.

Installation guide

Installation guide

Click the icon for installation support

Build a network

Build a network

Click the icon to learn how to build a network with smart RF

Resources

For more technical and specification information on this alarm, view our manual and datasheet.

Product manual

Product manual

Click the icon to download the product manual

Datasheet

Datasheet

Click the icon to download the product datasheet

Related FAQs

A Grade D1 system is required for:
  • New or materially altered dwellings, up to three storeys with no floor exceeding 200 m2.
  • Existing dwellings with poor or inadequate fire protection, up to three storeys with no floor exceeding 200 m2.
  • Individual dwelling units of two or more rooms in Houses in Multiple Occupation (HMOs) of one or two-storeys, with no floor exceeding 200 m2.
There are three Levels of Detection (LD). Generally the greater the fire risk the more comprehensive the system should be.
LD1 = Maximum Protection. Alarms in all circulation spaces that form part of escape routes and all areas where a fire might start.
LD2 = Medium Protection. All circulation spaces and escape routes (e.g.hallways and landings) are covered together with a provision of higher fire risk areas (e.g.kitchen and living rooms).
LD3 = Minimum Protection. Alarms in all circulation spaces that form part of escape routes.
* Ensure that a Grade D1 system is adequate for the dwelling you are installing the alarms in. You can obtain further information from your local fire service or building control department at your local council offices.
According to latest BS 5839‑6 standards, for maximum LD1 protection you should fit a smoke alarm in the following rooms: Hallway, Landing, Living Room, Bedroom, Airing / Meter Cupboards, Loft, Garage. A smoke alarm is not recommended for installation in a kitchen, you should install a heat alarm in kitchens.
For further guidance on BS 5836‑6, please visit our Standards and Regulations Section.

FireAngel Smart RF technology allows alarms to communicate wirelessly. When one alarm detects a hazard, all interconnected alarms will sound simultaneously, ensuring full-home coverage.

If you choose not to add a Gateway upon initial installation, you can add a Gateway to an existing network at any time in the future – this will allow for remote monitoring of devices as the Gateway will communicate with the FireAngel App using an internet connection, however, if the internet connection fails or cuts out the alarms will still continue to work and protect property, no internet connection means you will no receive any push notifications whilst the internet is not working.
Whilst BS 5839‑6 has previously been split into six varying Grades, each outlining the level of protection appropriate for certain properties and their corresponding levels of risk, the new update has altered the six sections, removing Grade B and Grade E, whilst Grade D and Grade F have been split into Grade D1 / Grade D2 and Grade F1 / Grade F2 respectively. Grade C has been revised and its recommendations expanded.
The 2019 grading system is as follows:
Grade A
Separate detectors, sounders and central control and indicating equipment with back-up power supply that conforms to British Standards BS EN 54.
Grade C
Separate detectors and sounders that are mains powered with back-up power supply and central control equipment.
Grade D1
A system of one or more mains powered detectors, each with a tamper‑proof standby supply consisting of a battery or batteries (such as FireAngel’s SM-SN-1 and HM-SN-1 alarm).
Grade D2
A system of one or more mains-powered detectors, each with an integral standby supply consisting of a user‑replaceable battery or batteries. (such as FireAngel’s SW1-PF-T and HW1-PF-T alarm).
Grade F1
A system of one or more battery-powered detectors powered by a tamper‑proof primary battery or batteries (such as FireAngel’s ST-622T, ST-750 alarm).
Grade F2
A system of one or more battery-powered detectors powered by a user‑replaceable primary battery or batteries. (such as FireAngel’s SB1-T alarm).
Please note: Grades B and E are no longer defined in BS 5839-6:2019.
See all faqs

Extend Your Protection

Smart RF Technology: When one alarm sounds, they all sound. Our Specification range features Smart RF technology, allowing easy setup of wireless or hybrid networks of mains and battery devices for full property protection. Specification products offer three levels of unrivalled protection, the range can be upgraded at any time to meet tenant needs or new regulations, setting the standard for performance.

Consider a connected solution: Add a Connected gateway to the Specification range, offering 24/7 remote monitoring. Designed for social housing or private landlords to ensure maximum protection and compliance across a property portfolio. The free FireAngel app provides real-time updates and notifications without needing property access. We have safety solutions for every need.

Smart city and communication network. Digital transformation. IoT (Internet of Things). ICT (Information Communication Technology).

Specification range

Specification 10 Year Kitchen Heat Alarm, Mains Powered image

HM-SN-1

Specification 10 Year Kitchen Heat Alarm, Mains Powered

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced...

Specification 10 Year Kitchen Heat Alarm, Mains Powered blog post
Specification Carbon Monoxide Alarm, 10 Year Sealed Battery  image

FS1326-T

Specification Carbon Monoxide Alarm, 10 Year Sealed Battery

Designed with installers in mind, this compliant, flexible, easy to fit Specification range...

Specification Carbon Monoxide Alarm, 10 Year Sealed Battery blog post
Specification Smart RF Radio Module image

FS1521W2-T

Specification Smart RF Radio Module

Easily upgrade your compatible Specification devices with the Smart RF module to create a wireless...

Specification Smart RF Radio Module blog post
Specification Mains Powered Relay - Wireless Interlink Only image

WRLYM-1EU

Specification Mains Powered Relay - Wireless Interlink Only

With an ultra slim design, our specification wireless interlink relay will extend any Smart RF...

Specification Mains Powered Relay - Wireless Interlink Only blog post
Specification Relay- Hardwire Interlink Only image

RLYM-1EU

Specification Relay- Hardwire Interlink Only

With an ultra slim design, our specification hardwired relay will extend any Smart RF network with...

Specification Relay- Hardwire Interlink Only blog post

Get in touch

Want to discuss how FireAngel can help you? Fill in a short form and book a call to speak to our dedicated trade support team.

Related Support Posts

Highlights from the 2026 InstallerSHOW image

Company

Highlights from the 2026 InstallerSHOW

FireAngel returned to the InstallerSHOW to host a panel discussion and exhibit a new product range

Highlights from the 2026 InstallerSHOW blog post
Understanding Spec+ Bluetooth™ Low Energy... image

Compliance

Understanding Spec+ Bluetooth™ Low Energy...

For social housing providers, landlords and professional installers, choosing the right fire alarm...

Understanding Spec+ Bluetooth™ Low Energy... blog post
Construction Products Reform: Why compliance... image

Compliance

Construction Products Reform: Why compliance...

The Government’s Construction Products Reform White Paper sets out a clearer direction for...

Construction Products Reform: Why compliance... blog post
Navigating third-party certification bodies... image

Navigating third-party certification bodies...

Customers need to understand certification bodies in order to make informed product choices.

Navigating third-party certification bodies... blog post
Five ways Spec+ helps contractors save time... image

Five ways Spec+ helps contractors save time...

Every minute saved on site helps contractors improve productivity, minimise resident disruption and...

Five ways Spec+ helps contractors save time... blog post
FireAngel compliance label solution:... image

FireAngel compliance label solution:...

Simplifying compliance processes through clearer records, stronger evidence and traceability.

FireAngel compliance label solution:... blog post