HW1-PF-T

Kitchen Heat Alarm with Push Fit Base

Heat alarm 5 Year Warranty Grade D2 Push to fit Mains Powered

Product description

We understand cost can be a huge factor for some projects, our mains 9V range offers a cost effective solution without compromising on quality or compliance, designed to save contractors time and money on installations. BS 5839‑6 recommends a heat alarm for a kitchen.

Developed with unique technology our enhanced heat alarms feature high performance thermistor sensing technology ensuring class A2 heat detection to ensure a quicker response and feature unique Push2Fit bases for quick and easy installation to save you time and money on installations.

  • Mains powered with replaceable 9V battery back-up
  • For use in kitchen, garage and loft
  • Provides class A2 heat detection (54°C-70°C) with advanced thermistor sensing technology
  • BS 5446-2:2003
  • Supplied with push fit base
  • Dust cap supplied to prevent dust or paint entering a device during installation or whilst building projects are in progress
  • Easy installation – Push fit base specifically designed for easy installation. Align arrows to ensure robust and secure connection
  • Interlink networks – Hardwire interlink up to 12 SW1-PF-T, HW1-PF-T, CW1-PF-T devices or use RF-BW-T base to wireless interlink multiple alarms
MoreLess

GET IN TOUCHPRODUCT SUPPORT

We understand cost can be a huge factor for some projects, our mains 9V range offers a cost effective solution without compromising on quality or compliance, designed to save contractors time and money on installations. BS 5839‑6 recommends a heat alarm for a kitchen.

Developed with unique technology our enhanced heat alarms feature high performance thermistor sensing technology ensuring class A2 heat detection to ensure a quicker response and feature unique Push2Fit bases for quick and easy installation to save you time and money on installations.

Installation & Setup

Get the help and support you need to easily set up and install your FireAngel alarm for instant protection.

Installation guide

Installation guide

Click the icon to find out more about installing your pro connected app

Build a network

Build a network

Click the icon to find out how to build a network of pro connected alarms

Resources

For more technical and specification information on this alarm, view our manual and datasheet.

Product manual

Product manual

Click the icon to download the product manual

Datasheet

Datasheet

Click the icon to download the product datasheet

Related FAQs

Whilst BS 5839‑6 has previously been split into six varying Grades, each outlining the level of protection appropriate for certain properties and their corresponding levels of risk, the new update has altered the six sections, removing Grade B and Grade E, whilst Grade D and Grade F have been split into Grade D1 / Grade D2 and Grade F1 / Grade F2 respectively. Grade C has been revised and its recommendations expanded.
The 2019 grading system is as follows:
Grade A
Separate detectors, sounders and central control and indicating equipment with back-up power supply that conforms to British Standards BS EN 54.
Grade C
Separate detectors and sounders that are mains powered with back-up power supply and central control equipment.
Grade D1
A system of one or more mains powered detectors, each with a tamper‑proof standby supply consisting of a battery or batteries (such as FireAngel’s SM-SN-1 and HM-SN-1 alarm).
Grade D2
A system of one or more mains-powered detectors, each with an integral standby supply consisting of a user‑replaceable battery or batteries. (such as FireAngel’s SW1-PF-T and HW1-PF-T alarm).
Grade F1
A system of one or more battery-powered detectors powered by a tamper‑proof primary battery or batteries (such as FireAngel’s ST-622T, ST-750 alarm).
Grade F2
A system of one or more battery-powered detectors powered by a user‑replaceable primary battery or batteries. (such as FireAngel’s SB1-T alarm).
Please note: Grades B and E are no longer defined in BS 5839-6:2019.

In the UK, landlords must install at least one smoke alarm on every storey of a rental property where there is a room used as living accommodation. In addition, a carbon monoxide alarm must be fitted in any room with a solid fuel-burning appliance.

Yes, our Mains 9V range of SW1-PF-T, HW1-PF-T, CW1-PF-T alarms can be hardwire interconnected with up to 12 smoke, heat or CO alarms or wirelessly interconnected with up to 50 alarms with the RF interlink base (RF-BW-T)

Yes, our FireAngel Specification range and FireAngel Mains 9V range of alarms are suitable for all domestic properties, this includes rental and new build properties.

See all faqs

Extend your protection

Protecting your properties and tenants is easier than ever with our range of smoke, heat, and carbon monoxide alarms. To ensure complete coverage, it’s essential to make sure you’re installing best practice and ensure compliance with your regional fire & CO safety laws.

For added peace of mind, upgrade to our Specification Range. These smart alarms, designed for social housing, can be interlinked (via hardwire or wireless) so when one alarm is triggered, all alarms in the property sound. Landlords can monitor and manage alarms remotely via the FireAngel Connected app, receiving device data and notifications without needing access to the property. The free app also allows for easy testing and instant notifications, showing the status of alarms, e.g. if they’ve been removed or need maintenance.

Get in touch today to see how our FireAngel Connected solution can support you and your tenants.

social-housing
Optical Smoke Alarm with Push Fit Base image

SW1-PF-T

Optical Smoke Alarm with Push Fit Base

We understand cost can be a huge factor for some projects, our mains 9V range offers a cost...

Carbon Monoxide Alarm with Push Fit Base image

CW1-PF-T

Carbon Monoxide Alarm with Push Fit Base

We understand cost can be a huge factor for some projects, our mains 9V range offers a cost...

RF Interlink Push Fit Base image

RF-BW-T

RF Interlink Push Fit Base

We understand cost can be a huge factor for some projects, our mains 9V range offers a cost...

Specification 10 Year Kitchen Heat Alarm, Mains Powered image

HM-SN-1

Specification 10 Year Kitchen Heat Alarm, Mains Powered

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced...

Specification 10 Year Kitchen Heat Alarm, Battery Powered image

FS1226-T

Specification 10 Year Kitchen Heat Alarm, Battery Powered

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced...

Specification Carbon Monoxide Alarm, 10 Year Sealed Battery  image

FS1326-T

Specification Carbon Monoxide Alarm, 10 Year Sealed Battery

Designed with installers in mind, this compliant, flexible, easy to fit Specification range...

Got a burning question? Get in touch

If you can't find what your looking for on our blogs and looking for further guidance and advice, our UK-based Customer Support team are on hand all week from 8:30am until 5:30pm, they can answer any further queries you may have on our products, solutions or services.

Related support posts

What the Renters’ Rights Bill means for UK... image

New Build

What the Renters’ Rights Bill means for UK...

The upcoming Renters’ Rights Bill represents a significant shift in the UK’s private rental...

FireAngel stands with the NEA on fuel... image

Community support

FireAngel stands with the NEA on fuel...

As temperatures drop and energy prices remain alarmingly high, FireAngel is proud to support...

Electrical fire safety week: protect your... image

Community support

Electrical fire safety week: protect your...

With Electrical Fire Safety Week (November 11th–17th) fast approaching, it’s the ideal time to...

What is the Decent Homes Standard? image

Compliance

What is the Decent Homes Standard?

View the definition of what is a decent home and guidance on how measures should be implemented as...

What is the Building Safety Act 2022? image

Compliance

What is the Building Safety Act 2022?

Read more on the requirements of the Building Safety Act 2022 which received Royal Assent on 28th...

Understanding the BS EN 50292:2023 Standard... image

Compliance

Understanding the BS EN 50292:2023 Standard...

The British Standard BS EN 50292:2023 offers recommendations on the installation and maintenance of...