An SCB10-R alarm rests on a wooden table with blurred plants in the background.
SCB10-R smoke and CO alarm on a white surface with green leaves in the upper left corner.
A white SCB10-R smoke and CO alarm on a light surface with a blurred background.
Side view of the SCB10-R alarm featuring vented openings and a black centre.
An SCB10-R alarm, its box, and leaflet sit on a cupboard beside a small potted plant.

SCB10-R-1

Combination Smoke and Carbon Monoxide Alarm

Smoke and CO sensing 3 Year Warranty Kitemark Sealed battery

Product description

The SCB10‑R smoke and CO alarm offers 2in1 protection and has been designed to protect properties against fire and CO.

This easy to install device has been rigorously tested by independent parties such as BSI Kitemark to ensure quality.

  • 10 year sealed lithium battery
  • 2 in 1 protection to protect properties against fire and CO
  • Rapid Detection of two deadly dangers – features both smoke and carbon monoxide (CO) sensors for detection of both dangers.
  • Clear indicators and alerts to allow you to see which is present when the alarm sounds.
  • Install alongside further units and a kitchen heat alarm for complete protection.

 

MoreLess

The SCB10‑R smoke and CO alarm offers 2in1 protection and has been designed to protect properties against fire and CO.

This easy to install device has been rigorously tested by independent parties such as BSI Kitemark to ensure quality.

Installation & Setup

Get the help and support you need to easily set up and install your FireAngel alarm for instant protection.

Installation guide

Installation guide

Click the icon to find out more about installing your pro connected app

Maintenance guide

Maintenance guide

Click the icon to find out how to maintain and test your alarm

Resources

For more technical and specification information on this alarm, view our manual and datasheet.

Product manual

Product manual

Click the icon to download the product manual

Datasheet

Datasheet

Click the icon to download the product datasheet

Related FAQs

According to latest BS 5839‑6 standards, for maximum LD1 protection you should fit a smoke alarm in the following rooms: Hallway, Landing, Living Room, Bedroom, Airing / Meter Cupboards, Loft, Garage. A smoke alarm is not recommended for installation in a kitchen, you should install a heat alarm in kitchens.
For further guidance on BS 5836‑6, please visit our Standards and Regulations Section.
Whilst BS 5839‑6 has previously been split into six varying Grades, each outlining the level of protection appropriate for certain properties and their corresponding levels of risk, the new update has altered the six sections, removing Grade B and Grade E, whilst Grade D and Grade F have been split into Grade D1 / Grade D2 and Grade F1 / Grade F2 respectively. Grade C has been revised and its recommendations expanded.
The 2019 grading system is as follows:
Grade A
Separate detectors, sounders and central control and indicating equipment with back-up power supply that conforms to British Standards BS EN 54.
Grade C
Separate detectors and sounders that are mains powered with back-up power supply and central control equipment.
Grade D1
A system of one or more mains powered detectors, each with a tamper‑proof standby supply consisting of a battery or batteries (such as FireAngel’s SM-SN-1 and HM-SN-1 alarm).
Grade D2
A system of one or more mains-powered detectors, each with an integral standby supply consisting of a user‑replaceable battery or batteries. (such as FireAngel’s SW1-PF-T and HW1-PF-T alarm).
Grade F1
A system of one or more battery-powered detectors powered by a tamper‑proof primary battery or batteries (such as FireAngel’s ST-622T, ST-750 alarm).
Grade F2
A system of one or more battery-powered detectors powered by a user‑replaceable primary battery or batteries. (such as FireAngel’s SB1-T alarm).
Please note: Grades B and E are no longer defined in BS 5839-6:2019.

For maximum protection for private rental properties smoke alarms must be installed on every floor where there is living accommodation (e.g., bedrooms, living rooms, hallways)
Heat alarms should be installed in kitchens and areas prone to false alarms.
Carbon monoxide alarms must be fitted in rooms with solid fuel appliances (e.g., wood-burning stoves, coal fires). Consider installing interconnected alarms to increase safety, especially in larger properties or properties with multiple tenants.

Refer to the product-specific manual for proper testing instructions. Regular testing helps ensure your alarms are working correctly and provides peace of mind.

See all faqs

Extend Your Protection

Protecting your properties and tenants is easier than ever with our range of smoke, heat, and carbon monoxide alarms. To ensure complete coverage, it’s essential to make sure you’re installing best practice and ensure compliance with your regional fire & CO safety laws.

For added peace of mind, upgrade to our Specification Range. These smart alarms, designed for social housing, can be interlinked (via hardwire or wireless) so when one alarm is triggered, all alarms in the property sound. Landlords can monitor and manage alarms remotely via the FireAngel Connected app, receiving device data and notifications without needing access to the property. The free app also allows for easy testing and instant notifications, showing the status of alarms, e.g. if they’ve been removed or need maintenance.

Get in touch today to see how our FireAngel Connected solution can support you and your tenants.

b6c688db90503333d2a7a173fc1b481a
Specification 10 Year Kitchen Heat Alarm, Battery Powered image

FS1226-T

Specification 10 Year Kitchen Heat Alarm, Battery Powered

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced...

Specification 10 Year Kitchen Heat Alarm, Battery Powered blog post
Sync‑It™ (NFC technology) Carbon Monoxide Alarm image

FA3328-EUT

Sync‑It™ (NFC technology) Carbon Monoxide Alarm

With Sync-It™ (NFC technology), logged device data can be easily extracted using the FireAngel...

Sync‑It™ (NFC technology) Carbon Monoxide Alarm blog post
Specification 10 Year Thermoptek Smoke Alarm, Mains Powered image

SM-SN-1

Specification 10 Year Thermoptek Smoke Alarm, Mains Powered

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced...

Specification 10 Year Thermoptek Smoke Alarm, Mains Powered blog post
Carbon Monoxide Alarm with Push Fit Base image

CW1-PF-T

Carbon Monoxide Alarm with Push Fit Base

We understand cost can be a huge factor for some projects, our mains 9V range offers a cost...

Carbon Monoxide Alarm with Push Fit Base blog post
Specification Smart RF Radio Module image

FS1521W2-T

Specification Smart RF Radio Module

Easily upgrade your compatible Specification devices with the Smart RF module to create a wireless...

Specification Smart RF Radio Module blog post
Specification Wireless Alarm Control Unit image

FS1524W2-T

Specification Wireless Alarm Control Unit

Our alarm control unit allows individuals to test interlinked Specification alarms, without the...

Specification Wireless Alarm Control Unit blog post

Get in touch

Want to discuss how FireAngel can help you? Fill in a short form and book a call to speak to our dedicated trade support team.

Related Support Posts

Highlights from the 2026 InstallerSHOW image

Company

Highlights from the 2026 InstallerSHOW

FireAngel returned to the InstallerSHOW to host a panel discussion and exhibit a new product range

Highlights from the 2026 InstallerSHOW blog post
Understanding Spec+ Bluetooth™ Low Energy... image

Compliance

Understanding Spec+ Bluetooth™ Low Energy...

For social housing providers, landlords and professional installers, choosing the right fire alarm...

Understanding Spec+ Bluetooth™ Low Energy... blog post
Construction Products Reform: Why compliance... image

Compliance

Construction Products Reform: Why compliance...

The Government’s Construction Products Reform White Paper sets out a clearer direction for...

Construction Products Reform: Why compliance... blog post
Navigating third-party certification bodies... image

Navigating third-party certification bodies...

Customers need to understand certification bodies in order to make informed product choices.

Navigating third-party certification bodies... blog post
Five ways Spec+ helps contractors save time... image

Five ways Spec+ helps contractors save time...

Every minute saved on site helps contractors improve productivity, minimise resident disruption and...

Five ways Spec+ helps contractors save time... blog post
FireAngel compliance label solution:... image

FireAngel compliance label solution:...

Simplifying compliance processes through clearer records, stronger evidence and traceability.

FireAngel compliance label solution:... blog post